Tags:
, view all tags

Sita Admin Corner

Italian Production sites

you can find here the list of Italian sites.

National Squid service for CVMFS

If you are going to run jobs on your cluster using CernVM-FS you should also use squids to cache data at your site. In case you decide to not install a squid service at your site or in case of failover at your site, Italian NGI provide a National squid service accessible only by registered italian sites.

We have two squids with ACLs based source and destination. If you decide to use this service, please contact igi-noc@lists.italiangrid.it providing:

  • the network information of your WNs (eg 131.154.101.0/255.255.255.0);
  • the cvmfs server(s) your WNs need to contact (eg: cvmfs-gridit.cnaf.infn.it);
  • add the line CVMFS_HTTP_PROXY="http://squid01.cnaf.infn.it:3128|http://squid02.cnaf.infn.it:3128" to the configuration of the cvmfs client on each WN (usually under /etc/cvmfs/config.d/).

Eg. for VO gridit: /etc/cvmfs/config.d/gridit..conf:CVMFS_HTTP_PROXY="http://squid01.cnaf.infn.it:3128|http://squid02.cnaf.infn.it:3128"

Using National Squid service for failover

If you run local squid service, you can also add the national squid servers for failover case. CVMFS_HTTP_PROXY is used to specify the squid server(s) to be used for local caching. It supports both load balance and failover:

Configuration test for failover

Thanks to E. Mazzoni, INFN-PISA.
# cmssquid.pi.infn.it and cmssquid2.pi.infn.it primary group, squid01.cnaf.infn.it and squid01.cnaf.infn.it failover group

# Normal behaviour
[root@stormgf1 ~]# cvmfs_talk -i belle.cern.ch proxy info
Load-balance groups:
[0] http://cmssquid.pi.infn.it:3128, http://cmssquid2.pi.infn.it:3128
[1] http://squid01.cnaf.infn.it:3128, http://squid02.cnaf.infn.it:3128
Active proxy: [0] http://cmssquid.pi.infn.it:3128 

# Failover behaviour (cmssquid.pi.infn.it and cmssquid2.pi.infn.it denied by acl on router)
[root@stormgf1 ~]# cvmfs_talk -i belle.cern.ch proxy info
Load-balance groups:
[0] http://cmssquid2.pi.infn.it:3128, http://cmssquid.pi.infn.it:3128
[1] http://squid02.cnaf.infn.it:3128, http://squid01.cnaf.infn.it:3128
Active proxy: [1] http://squid02.cnaf.infn.it:3128 

Table

List of the cvmfs servers and sites supported by national squid server.
cvmfs servers
cernvmfs.gridpp.rl.ac.uk
cvmfs02.grid.sinica.edu.tw
cvmfs-atlas-nightlies.cern.ch
cvmfs.fnal.gov
cvmfs-gridit.cnaf.infn.it
cvmfs.racf.bnl.gov
cvmfs-repo-superb.cnaf.infn.it
cvmfs-stratum-one.cern.ch
igi-cvmfs.cnaf.infn.it

Sites Note
IGI-BOLOGNA primario
INFN-CATANIA failover
INFN-PISA failover
INFN-ROMA2 primario
TRIGRID-INFN-CATANIA failover
UNI-PERUGIA primario

Useful link

Upgrade Plan

Tutorial

V Corso di formazione INFN per amministratori di siti GRID
Agenda
Tutorial WNoDes
Tutorial StoRM
Tutorial Cream
Tutorial Yaim

Notes about services from IGI middleware, based on EMI/UMD

These notes are provided by site admins on a best effort base as a contribution to the IGI communities and MUST not be considered as a subsitute of the Official IGI documentation. This document is addressed to site administrators responsible for middleware installation and configuration.

Information about ARGUS and gLexec Deployment

* Actions for site-admins

Table about Installation and Configuration of Grid services EMI-3

The core services are those that are typically shared by multiple VOs and which interact with the resources made available at the Grid Site level. They should not be installed at Site level.
Service Type Service Name Installation Notes Provider O.S.
CORE service LCG file Catalog (LFC) Notes about Installation and Configuration of EMI-3 (SL6) LFC server EMI-3 SL6
CORE service MyProxy Notes about MyProxy - EMI-3 - SL6 EMI-3 SL6

Table about Installation and Configuration of Grid services EMI-2

The core services are those that are typically shared by multiple VOs and which interact with the resources made available at the Grid Site level. They should not be installed at Site level.
Service Type Service Name Installation Notes Provider O.S.
SITE service User Interface (UI) Notes about installation and configuration of EMI-UI - EMI-2 SL6 EMI-2 SL6
SITE service Torque server stand alone (no cream) Notes about torque server - EMI-2 SL6 EMI-2 SL6
SITE service Cream Computing Element (without TORQUE) with MPI Notes about Cream without Torque with MPI - EMI-2 SL6 EMI-2 SL6
SITE service Worker Node (WN) + TORQUE + MPI + GLEXEC Notes about WN (torque, mpi, glexec) - EMI-2 SL6 EMI-2 SL6
SITE service Cream Computing Element (CE CREAM) + TORQUE TODO EMI-2
SITE service Worker Node (WN) + TORQUE + GLEXEC TODO EMI-2
SITE service Worker Node (WN) + TORQUE + MPI TODO EMI-2
SITE service site-bdii Notes about site-bdii EMI-2 SL6 EMI-2 SL6
SITE service StoRM Storage Element (StoRM SE) TODO EMI-2
SITE/CORE service Home Location Register (HLR) TODO IGI
CORE service MyProxy Notes about MyProxy - EMI-2 - SL6 EMI-2 SL6
CORE service top-bdii Notes about top-bdii - EMI-2 - SL6 EMI-2 SL6
CORE service Workload Management System (WMS) TODO EMI-2
CORE service Logging & Bookepping (LB) TODO EMI-2
CORE service LCG file Catalog (LFC) Notes about Installation and Configuration of EMI-2 (SL5) LFC server EMI-2 SL5
CORE service File Transfer Service (FTS) TODO EMI-2
CORE service VOMS Notes about Installation and Configuration of EMI2 VOMS-MySQL on SL6 EMI-2

References

  1. About IGI - Italian Grid infrastructure
  2. About IGI Release
  3. IGI Official Installation and Configuration guide
  4. Troubleshooting Guide for Operational Errors on EGI Sites
  5. Grid Administration FAQs page


Outdated Guides

gLite middleware (OUTDATED)

Notes about services based on gLite middleware

How to join, installing and configure igi.italaingrid.it VO on your site (OUTDATED)

How to join, installing and configure igi.italaingrid.it VO on your site

Table about Installation and Configuration of Grid services EMI-1 (OUTDATED)

The core services are those that are typically shared by multiple VOs and which interact with the resources made available at the Grid Site level. They should not be installed at Site level.
Service Type Service Name Installation Notes Provider
SITE service User Interface (UI) Notes about Installation and Configuration of UI EMI-1
SITE service Cream Computing Element (CE CREAM) + TORQUE with ARGUS Notes about Installation and Configuration of CREAM and TORQUE EMI-1
SITE service Cream Computing Element (CE CREAM) for TORQUE Notes about Installation and Configuration of CREAM for TORQUE EMI-1
SITE service Worker Node (WN) + TORQUE + GLEXEC Notes about Installation and Configuration of WN TORQUE GLEXEC EMI-1
SITE service Worker Node (WN) + TORQUE + MPI Notes about Installation and Configuration of WN TORQUE MPI EMI-1
SITE service Stand Alone TORQUE Server Notes about Installation and Configuration of TORQUE EMI-1
SITE service site-bdii Notes about Installation and Configuration of a Site BDII EMI-1
SITE service StoRM Storage Element (StoRM SE) TODO EMI-1
SITE/CORE service Home Location Register (HLR) TODO EMI-1
CORE service MyProxy Notes about Installation and Configuration of myproxy EMI-1
CORE service top-bdii Notes about Installation and Configuration of a Top BDII EMI-1
CORE service Workload Management System (WMS) Notes about Installation and Configuration of a WMS and LB EMI-1
CORE service Logging & Bookepping (LB) TODO EMI-1
CORE service LCG file Catalog (LFC) Notes about Installation and Configuration of a LFC server EMI-1
CORE service File Transfer Service (FTS) TODO EMI-1
CORE service VOMS Notes about Installation and Configuration of VOMS-MySQL EMI-1
Edit | Attach | PDF | History: r70 | r61 < r60 < r59 < r58 | Backlinks | Raw View | More topic actions...
Topic revision: r59 - 2013-10-24 - AlessandroPaolini
 
  • Edit
  • Attach
This site is powered by the TWiki collaboration platformCopyright © 2008-2024 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.